Nora Lighting

6" Marquise I, Non IC Remodel Housing by Nora Lighting

$136.17 $190.64
Loading reviews...
  • 6" Marquise I, Non IC Remodel Housing by Nora Lighting
  • 6" Marquise I, Non IC Remodel Housing by Nora Lighting

Nora Lighting

6" Marquise I, Non IC Remodel Housing by Nora Lighting

$136.17 $190.64
Loading reviews...

Nora Lighting 6" Marquise I, Non-IC Remodel Housing

Dedicated remodel housing for use in Non-IC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.

CONSTRUCTION
Housing: 0.040 aluminum housing adjusts to a maximum ceiling thickness of 5/8” (16mm). Housing terminates at a 1/4” ceiling flange for even positioning of housing angle within the ceiling. Structural arm consists of 0.050 steel and connects to housing with j-box and ballast. Integral springs brackets provided.

Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM283 Air-Tight requirements.

Mounting: Four high tension tempered steel springs secure remodel housing to 5/8” thick (max) ceiling (Hole cutout template provided for convenience).

Junction Box: Prewired 25 cubic inch 0.064” thick galvanized steel, with five 1/2”, two 3/4” knockouts, four Romex® pryouts, and snap on covers. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).

CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3” from thermal insulation and 1/2” from adjacent building components.
IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.

Electrical
Input Voltage: 120V or 277V
Delivered Lumens / Wattage:
NHRM-612: 1246lm / 16W
NHRM-620: 1951lm / 26W
Operating Temp.: 0˚C to 75˚C ambient temperature
Comfort Dim: Available in 850-2000lm
Dimming: 
LE1: 120V Input; Triac/ELV/0-10V dimming1
LE2: 277V Input; 0-10V dimming1
LE4: 120V Input; Triac/ELV/0-10V dimming1

Emergency LED Driver (BSL17C-C2)
· Up to 7.5W emergency illumination with LEDs.
· Illumination Time: 90min
· Voltage: 120/277 VAC, 60Hz
· Output Voltage: 15.0-50.0 VDC

Labels and listings
· cULus Listed for Damp Location w/ Feed Through
· cULus Wet Listed (Only with designated trims)
· Meets or exceeds ASTM-283 Air-Tight Requirements 

Item Code
NHRM-6

Return Policy
All sales are final, and not eligible for return. We accept returns for exchange for items damaged in transit, or if the item is defective.

  • Gallery
  • Description
  • Reviews

Nora Lighting 6" Marquise I, Non-IC Remodel Housing

Dedicated remodel housing for use in Non-IC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.

CONSTRUCTION
Housing: 0.040 aluminum housing adjusts to a maximum ceiling thickness of 5/8” (16mm). Housing terminates at a 1/4” ceiling flange for even positioning of housing angle within the ceiling. Structural arm consists of 0.050 steel and connects to housing with j-box and ballast. Integral springs brackets provided.

Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM283 Air-Tight requirements.

Mounting: Four high tension tempered steel springs secure remodel housing to 5/8” thick (max) ceiling (Hole cutout template provided for convenience).

Junction Box: Prewired 25 cubic inch 0.064” thick galvanized steel, with five 1/2”, two 3/4” knockouts, four Romex® pryouts, and snap on covers. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).

CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3” from thermal insulation and 1/2” from adjacent building components.
IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.

Electrical
Input Voltage: 120V or 277V
Delivered Lumens / Wattage:
NHRM-612: 1246lm / 16W
NHRM-620: 1951lm / 26W
Operating Temp.: 0˚C to 75˚C ambient temperature
Comfort Dim: Available in 850-2000lm
Dimming: 
LE1: 120V Input; Triac/ELV/0-10V dimming1
LE2: 277V Input; 0-10V dimming1
LE4: 120V Input; Triac/ELV/0-10V dimming1

Emergency LED Driver (BSL17C-C2)
· Up to 7.5W emergency illumination with LEDs.
· Illumination Time: 90min
· Voltage: 120/277 VAC, 60Hz
· Output Voltage: 15.0-50.0 VDC

Labels and listings
· cULus Listed for Damp Location w/ Feed Through
· cULus Wet Listed (Only with designated trims)
· Meets or exceeds ASTM-283 Air-Tight Requirements 

Item Code
NHRM-6