Nora Lighting

5" Marquise I, Non IC New Construction Housing 1778lm by Nora Lighting

$136.17
Loading reviews...
  • 5" Marquise I, Non IC New Construction Housing 1778lm by Nora Lighting
  • 5" Marquise I, Non IC New Construction Housing 1778lm by Nora Lighting

Nora Lighting

5" Marquise I, Non IC New Construction Housing 1778lm by Nora Lighting

$136.17
Loading reviews...

Nora Lighting 5" Marquise I, Non-IC New Construction Housing 1778lm

Dedicated new construction housing for installation in NonIC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.

CONSTRUCTION
Plaster Frame: 0.040 steel frame with integral bar hanger brackets. Brackets can accommodate longer 27” accessory flat bar hangers. Brackets run along all sides of frame to allow bar hangers to be run parallel or perpendicular to junction box.

Housing: 0.040 aluminum one-piece can. Adjustable ceiling thickness from 3/8” to 7/8”.

Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM-283 Air-Tight requirements.

Bar Hangers: Two 13-3/4” to 24-1/2” adjustable bar hangers with captive nails are included on frame. Bar hangers are parallel to junction box, but can be repositioned 90º perpendicular to junction box if
desired. “L” Shaped bar hanger foot to align to bottom of construction joist. A T-Bar notch allow for easy installation in a suspended ceiling.

Junction Box: Prewired 25 cubic inch 0.064” thick galvanized steel, with seven 1/2” knockouts, four Romex® pryouts, and snap on covers. All leads are #18AWG wire, the ground wire is connected to the
bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).

CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3” from thermal insulation and 1/2” from adjacent building components.

IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.

Electrical
Input Voltage: 120V or 277V
Delivered Lumens / Wattage:
NHM-520: 1778lm / 26W

Operating Temp.: 0˚C to 45˚C ambient temperature
Comfort Dim: Available in 850-2000lm
Driver / Dimming
LE1: 120V Input; Triac/ELV/0-10V dimming
LE2: 277V Input; 0-10V dimming1
LE4: 120V Input; Triac/ELV/0-10V dimming


Emergency LED Driver (BSL17C-C2)
· Up to 7.5W emergency illumination with LEDs.
· Illumination Time: 90min
· Voltage: 120/277 VAC, 60Hz
· Output Voltage: 15.0-50.0 VDC

Labels and listings
· cULus Listed for Damp Location w/ Feed Through
· cULus Wet Listed (Only with designated trims)
· Meets or exceeds ASTM-283 Air-Tight Requirements 

Item Code
NHM-5-1778lm

Return Policy
All sales are final, and not eligible for return. We accept returns for exchange for items damaged in transit, or if the item is defective.

  • Gallery
  • Description
  • Reviews

Nora Lighting 5" Marquise I, Non-IC New Construction Housing 1778lm

Dedicated new construction housing for installation in NonIC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.

CONSTRUCTION
Plaster Frame: 0.040 steel frame with integral bar hanger brackets. Brackets can accommodate longer 27” accessory flat bar hangers. Brackets run along all sides of frame to allow bar hangers to be run parallel or perpendicular to junction box.

Housing: 0.040 aluminum one-piece can. Adjustable ceiling thickness from 3/8” to 7/8”.

Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM-283 Air-Tight requirements.

Bar Hangers: Two 13-3/4” to 24-1/2” adjustable bar hangers with captive nails are included on frame. Bar hangers are parallel to junction box, but can be repositioned 90º perpendicular to junction box if
desired. “L” Shaped bar hanger foot to align to bottom of construction joist. A T-Bar notch allow for easy installation in a suspended ceiling.

Junction Box: Prewired 25 cubic inch 0.064” thick galvanized steel, with seven 1/2” knockouts, four Romex® pryouts, and snap on covers. All leads are #18AWG wire, the ground wire is connected to the
bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).

CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3” from thermal insulation and 1/2” from adjacent building components.

IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.

Electrical
Input Voltage: 120V or 277V
Delivered Lumens / Wattage:
NHM-520: 1778lm / 26W

Operating Temp.: 0˚C to 45˚C ambient temperature
Comfort Dim: Available in 850-2000lm
Driver / Dimming
LE1: 120V Input; Triac/ELV/0-10V dimming
LE2: 277V Input; 0-10V dimming1
LE4: 120V Input; Triac/ELV/0-10V dimming


Emergency LED Driver (BSL17C-C2)
· Up to 7.5W emergency illumination with LEDs.
· Illumination Time: 90min
· Voltage: 120/277 VAC, 60Hz
· Output Voltage: 15.0-50.0 VDC

Labels and listings
· cULus Listed for Damp Location w/ Feed Through
· cULus Wet Listed (Only with designated trims)
· Meets or exceeds ASTM-283 Air-Tight Requirements 

Item Code
NHM-5-1778lm