{"product_id":"4-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-28w-nhioicdcp-425-by-nora","title":"4\" Iolite LED Dedicated Chicago Plenum New Construction Housing, 28W | Nora NHIOICDCP-425","description":"\u003cdiv class=\"lm-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eNora's NHIOICDCP-425\u003c\/strong\u003e is the Chicago Plenum, new construction housing for 4\" Iolite high lumen trims. It holds the 28W driver; the trim you choose sets the look and the beam.\u003c\/p\u003e\n\u003cp\u003eIt is rated for insulated ceilings, so insulation can touch it, and the driver slides out from the room side without tools.\u003c\/p\u003e\n\u003cdiv class=\"lm-badges lm-ratings\" style=\"display:flex;flex-wrap:wrap;gap:8px;margin:12px 0 18px\"\u003e\n\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 3l7 3v5c0 4.5-3 8.3-7 10-4-1.7-7-5.5-7-10V6l7-3z\"\u003e\u003c\/path\u003e\u003cpath d=\"M8.5 12l2.5 2.5 4.5-5\"\u003e\u003c\/path\u003e\u003c\/svg\u003ecULus listed\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 4c-2.5 3.5-4.5 6-4.5 8.5a4.5 4.5 0 009 0C16.5 10 14.5 7.5 12 4z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eDamp location (wet with listed trim)\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003crect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\"\u003e\u003c\/rect\u003e\u003cpath d=\"M9 9v6M12 9v6M15 9v6\"\u003e\u003c\/path\u003e\u003c\/svg\u003eIC rated\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003crect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\"\u003e\u003c\/rect\u003e\u003cpath d=\"M9 9v6M12 9v6M15 9v6\"\u003e\u003c\/path\u003e\u003c\/svg\u003eChicago Plenum (CCEA)\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M13 3L5 13h6l-1 8 8-10h-6l1-8z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eAirtight ASTM E283\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003ccircle cx=\"12\" cy=\"9\" r=\"5.5\"\u003e\u003c\/circle\u003e\u003cpath d=\"M9 13.8L8 21l4-2 4 2-1-7.2\"\u003e\u003c\/path\u003e\u003cpath d=\"M10 9l1.5 1.5L14.5 7.5\"\u003e\u003c\/path\u003e\u003c\/svg\u003e5-year warranty\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M5 19c0-8 5-13 14-14-1 9-6 14-14 14z\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 19l8-8\"\u003e\u003c\/path\u003e\u003c\/svg\u003eRoHS\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBuilt for the Ceiling You Have\u003c\/h2\u003e\n\u003cp\u003eIt is IC rated for direct contact with insulation (not spray foam) and airtight to ASTM E283, under 2 cubic feet per minute of air leakage. Nora lists it as CCEA compliant (City of Chicago Environmental Air).\u003c\/p\u003e\n\u003cp\u003eThis is the 28W housing. The 28W output pairs with the 4\" Iolite trims that Nora lists for it below. Some Iolite trims are rated for 24W maximum and are not on that list.\u003c\/p\u003e\n\u003ch2\u003eIn the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum shallow housing for a 1\/2\" ceiling\u003c\/li\u003e\n\u003cli\u003eTool-less slide-out driver assembly, 28W (120\/277V input; Triac \/ ELV \/ 0-10V dimming)\u003c\/li\u003e\n\u003cli\u003eTwo adjustable bar hangers, 13-3\/4\" to 24-1\/2\", with captive nails and a T-bar notch\u003c\/li\u003e\n\u003cli\u003ePre-wired 25 cu. in. galvanized steel junction box with seven 1\/2\" knockouts and Romex strain relief\u003c\/li\u003e\n\u003cli\u003eAir sealing gasket (see the install sheet)\u003c\/li\u003e\n\u003cli\u003eEM2 version only: compact emergency driver on the junction box (90 minutes at 6W in emergency mode, 24-hour recharge, 3W while charging), with remote test switch and 3' cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot in the box: the trim. The LED module and optics come with the trim. Access from above the ceiling is needed.\u003c\/p\u003e\n\u003ch2\u003eChoose Your Trim (Required)\u003c\/h2\u003e\n\u003cp\u003eTrims Nora lists for this 28W housing. Wet-listed trims make the installed fixture wet rated.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-adjustable-cone-reflector-1000lm-14w-nio-4rc-by-nora\"\u003eNIO-4RC\u003c\/a\u003e – Round adjustable cone reflector\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-square-adjustable-cone-reflector-nio-4sc-by-nora\"\u003eNIO-4SC\u003c\/a\u003e – Square adjustable cone reflector\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-adjustable-gimbal-nio-4rg-by-nora\"\u003eNIO-4RG\u003c\/a\u003e – Round adjustable gimbal\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-reflector-nio-4rndc-by-nora\"\u003eNIO-4RNDC\u003c\/a\u003e – Round downlight reflector\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-square-reflector-with-round-aperture-nio-4sndc-by-nora\"\u003eNIO-4SNDC\u003c\/a\u003e – Square downlight, round aperture\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-square-reflector-with-square-aperture-1000lm-14w-3000k-nio-4sndsq-by-nora\"\u003eNIO-4SNDSQ\u003c\/a\u003e – Square downlight, square aperture\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-pinhole-nio-4rph-by-nora\"\u003eNIO-4RPH\u003c\/a\u003e – Round pinhole\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-adjustable-pinhole-nio-4rpha-by-nora\"\u003eNIO-4RPHA\u003c\/a\u003e – Round adjustable pinhole\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-adjustable-slot-aperture-nio-4rsl-by-nora\"\u003eNIO-4RSL\u003c\/a\u003e – Round adjustable slot aperture\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-bullnose-nio-4rnb-by-nora\"\u003eNIO-4RNB\u003c\/a\u003e – Round bullnose\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-led-round-trimless-downlight-1000lm-14w-3000k-nio-4rtlndc-by-nora\"\u003eNIO-4RTLNDC\u003c\/a\u003e – Round trimless downlight\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-iolite-plus-round-trimless-downlight-1500lm-2000lm-2500lm-varies-by-housing-nio-4prtlndc-by-nora\"\u003eNIO-4PRTLNDC\u003c\/a\u003e – PLUS round trimless downlight\u003c\/li\u003e\n\u003cli\u003eNIO-4SG – Square adjustable gimbal\u003c\/li\u003e\n\u003cli\u003eNIO-4SNB – Square bullnose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePairs Well With\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/2-inch-ceiling-extension-collar-for-4-inch-iolite-new-construction-housings-nio-4extc2-by-nora\"\u003eNIO-4EXTC2\u003c\/a\u003e – Extension collar for ceilings up to 2\" thick\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/2-inch-wood-ceiling-extension-collar-for-4-inch-iolite-new-construction-housings-nio-4wcc2-by-nora\"\u003eNIO-4WCC2\u003c\/a\u003e – Wood ceiling collar, lets flanged trims sit in wood ceilings up to 2\" thick\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-round-flush-mount-mud-ring-for-4-inch-iolite-round-trims-nio-fmmr-4r-by-nora\"\u003eNIO-FMMR-4R\u003c\/a\u003e – Flush mount mud ring for round flanged trims\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-square-flush-mount-mud-ring-for-4-inch-iolite-square-trims-nio-fmmr-4s-by-nora\"\u003eNIO-FMMR-4S\u003c\/a\u003e – Flush mount mud ring for square flanged trims\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/4-inch-round-trimless-mud-ring-for-4-inch-iolite-plus-round-trimless-nio-tlmr-4pr-by-nora\"\u003eNIO-TLMR-4PR\u003c\/a\u003e – Trimless mud ring for the PLUS round trimless\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/emergency-led-driver-with-remote-test-switch-nepk-07ledunv-by-nora\"\u003eNEPK-07LEDUNV\u003c\/a\u003e – Remote emergency battery with test switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ctable class=\"lm-table\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eNora Lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eNHIOICDCP-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCollection\u003c\/th\u003e\n\u003ctd\u003eIolite 4\" high lumen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eRecessed housing, new construction (IC airtight, Chicago Plenum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCeiling Cut-Out\u003c\/th\u003e\n\u003ctd\u003e4-5\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCeiling Thickness\u003c\/th\u003e\n\u003ctd\u003e1\/2\" as supplied; up to 2\" with NIO-4EXTC2 (maximum for all installs, including trimless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003e28W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e120\/277V (LE4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eDimming\u003c\/th\u003e\n\u003ctd\u003eTriac \/ ELV \/ 0-10V (LE4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003ePower Factor\u003c\/th\u003e\n\u003ctd\u003e0.90 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eEmergency Option\u003c\/th\u003e\n\u003ctd\u003eEM2 integrated emergency driver (the pre-wired PEM option is not compatible with Chicago Plenum housings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eBar Hangers\u003c\/th\u003e\n\u003ctd\u003e13-3\/4\" to 24-1\/2\" adjustable, parallel to the junction box or turned 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eJunction Box\u003c\/th\u003e\n\u003ctd\u003e25 cu. in., 0.064\" galvanized steel, up to 8 no. 12 AWG through-branch conductors (6 with EM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eInsulation Contact\u003c\/th\u003e\n\u003ctd\u003eIC rated (not for direct contact with spray foam)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eAir Tightness\u003c\/th\u003e\n\u003ctd\u003eASTM E283, under 2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eSafety Listing\u003c\/th\u003e\n\u003ctd\u003ecULus listed for damp locations; wet with a wet-listed trim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eEnvironmental\u003c\/th\u003e\n\u003ctd\u003eRoHS compliant; FCC compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5-year limited warranty (Nora Lighting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eNora Part Numbers\u003c\/th\u003e\n\u003ctd\u003e2 options (listed below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpec Sheets \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2020\/04\/NHIOICD-415_420_425_spec.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpec sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2020\/04\/IS-NHIOICD-HL.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2020\/04\/Iolite-High-Lumen_Flyer.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIolite high lumen flyer (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2018\/05\/NHIOICD-4HL_revit.zip\" target=\"_blank\" rel=\"noopener\"\u003eRevit file (ZIP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2020\/04\/Iolite-Catalog.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIolite collection catalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2019\/02\/Limited-Warranty-Five-Year.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNora 5-year limited warranty (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/n2aYcDFuVWA\" target=\"_blank\" rel=\"noopener\"\u003eProduct video\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot the Right Fit If…\u003c\/h2\u003e\n\u003cp\u003eYou are working in a finished ceiling with no access from above, or you need a trim rated for 24W maximum. Use a remodel housing or a can-less trim for finished ceilings.\u003c\/p\u003e\n\u003ch2\u003eQuestions We Hear Most\u003c\/h2\u003e\n\u003ch3\u003eDoes the housing include the light?\u003c\/h3\u003e\n\u003cp\u003eNo. The LED and optics come with the 4\" Iolite trim you pair it with. The housing supplies the driver.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between this and the IC airtight version?\u003c\/h3\u003e\n\u003cp\u003eThis is the Chicago Plenum version, listed by Nora as CCEA compliant (City of Chicago Environmental Air). Both are IC rated and airtight. Check your local code to see which one you need.\u003c\/p\u003e\n\u003ch3\u003eWhat does the EM2 option do?\u003c\/h3\u003e\n\u003cp\u003eIt adds an emergency driver that keeps the light on for 90 minutes at 6W during an outage. The battery draws 3W while it charges. It needs access above the ceiling.\u003c\/p\u003e\n\u003ch3\u003eCan it touch insulation?\u003c\/h3\u003e\n\u003cp\u003eYes, it is IC rated for direct contact with insulation, but not with spray foam.\u003c\/p\u003e\n\u003ch3\u003eMy ceiling is thicker than 1\/2\". Will it fit?\u003c\/h3\u003e\n\u003cp\u003eAdd the NIO-4EXTC2 extension collar for ceilings up to 2\" thick, the maximum for any install.\u003c\/p\u003e\n\u003ch3\u003eWhich trims fit?\u003c\/h3\u003e\n\u003cp\u003eThe 4\" Iolite trims listed above. Trims rated for 24W maximum are not on Nora's list for this 28W housing.\u003c\/p\u003e\n\u003ch2\u003eWhy We Love It\u003c\/h2\u003e\n\u003cp\u003eA 4\" Iolite downlight lives or dies by its housing. This one keeps the driver serviceable from below, the ceiling airtight above, and meets the Chicago Plenum listing.\u003c\/p\u003e\n\u003ch2\u003eShipping Info\u003c\/h2\u003e\n\u003ctable class=\"lm-shipping-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing Time\u003c\/th\u003e\n\u003ctd\u003eIn-stock items typically leave within 2–3 business days.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShips From\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003eFree shipping on orders over $100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFind Your Part Number\u003c\/h2\u003e\n\u003cp\u003eEach driver option on this page is its own Nora part number, shown as the SKU when you select it (the SKU is the Nora part number with an LM-NORA- prefix): NHIOICDCP-425LE4 is the 120\/277V, Triac \/ ELV \/ 0-10V version. NHIOICDCP-425LE4-EM2 is the same with the integrated emergency driver.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@graph\": [{\"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Does the housing include the light?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. The LED and optics come with the 4\\\" Iolite trim you pair it with. The housing supplies the driver.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between this and the IC airtight version?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"This is the Chicago Plenum version, listed by Nora as CCEA compliant (City of Chicago Environmental Air). Both are IC rated and airtight. Check your local code to see which one you need.\"}}, {\"@type\": \"Question\", \"name\": \"What does the EM2 option do?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It adds an emergency driver that keeps the light on for 90 minutes at 6W during an outage. The battery draws 3W while it charges. It needs access above the ceiling.\"}}, {\"@type\": \"Question\", \"name\": \"Can it touch insulation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, it is IC rated for direct contact with insulation, but not with spray foam.\"}}, {\"@type\": \"Question\", \"name\": \"My ceiling is thicker than 1\/2\\\". Will it fit?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Add the NIO-4EXTC2 extension collar for ceilings up to 2\\\" thick, the maximum for any install.\"}}, {\"@type\": \"Question\", \"name\": \"Which trims fit?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The 4\\\" Iolite trims listed above. Trims rated for 24W maximum are not on Nora's list for this 28W housing.\"}}]}, {\"@id\": \"\/products\/4-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-28w-nhioicdcp-425-by-nora#product\", \"@type\": \"ProductGroup\", \"name\": \"Nora 4\\\" Iolite LED Dedicated Chicago Plenum New Construction Housing, 28W NHIOICDCP-425\", \"productGroupID\": \"NHIOICDCP-425\", \"brand\": {\"@type\": \"Brand\", \"name\": \"Nora Lighting\"}, \"manufacturer\": {\"@type\": \"Organization\", \"name\": \"Nora Lighting\", \"url\": \"https:\/\/noralighting.com\"}, \"category\": \"Recessed housing\", \"variesBy\": [\"Voltage \u0026 Driver\"], \"material\": \"Aluminum\", \"additionalProperty\": [{\"@type\": \"PropertyValue\", \"name\": \"Brand\", \"value\": \"Nora Lighting\"}, {\"@type\": \"PropertyValue\", \"name\": \"Model Number\", \"value\": \"NHIOICDCP-425\"}, {\"@type\": \"PropertyValue\", \"name\": \"Collection\", \"value\": \"Iolite 4\\\" high lumen\"}, {\"@type\": \"PropertyValue\", \"name\": \"Product Type\", \"value\": \"Recessed housing, new construction (IC airtight, Chicago Plenum)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Ceiling Cut-Out\", \"value\": \"4-5\/16\\\"\"}, {\"@type\": \"PropertyValue\", \"name\": \"Ceiling Thickness\", \"value\": \"1\/2\\\" as supplied; up to 2\\\" with NIO-4EXTC2 (maximum for all installs, including trimless)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Input Power\", \"value\": \"28W\"}, {\"@type\": \"PropertyValue\", \"name\": \"Input Voltage\", \"value\": \"120\/277V (LE4)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Dimming\", \"value\": \"Triac \/ ELV \/ 0-10V (LE4)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Power Factor\", \"value\": \"0.90 or higher\"}, {\"@type\": \"PropertyValue\", \"name\": \"Emergency Option\", \"value\": \"EM2 integrated emergency driver (the pre-wired PEM option is not compatible with Chicago Plenum housings)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Bar Hangers\", \"value\": \"13-3\/4\\\" to 24-1\/2\\\" adjustable, parallel to the junction box or turned 90°\"}, {\"@type\": \"PropertyValue\", \"name\": \"Junction Box\", \"value\": \"25 cu. in., 0.064\\\" galvanized steel, up to 8 no. 12 AWG through-branch conductors (6 with EM2)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Insulation Contact\", \"value\": \"IC rated (not for direct contact with spray foam)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Air Tightness\", \"value\": \"ASTM E283, under 2 CFM\"}, {\"@type\": \"PropertyValue\", \"name\": \"Safety Listing\", \"value\": \"cULus listed for damp locations; wet with a wet-listed trim\"}, {\"@type\": \"PropertyValue\", \"name\": \"Environmental\", \"value\": \"RoHS compliant; FCC compliant\"}, {\"@type\": \"PropertyValue\", \"name\": \"Warranty\", \"value\": \"5-year limited warranty (Nora Lighting)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Nora Part Numbers\", \"value\": \"2 options (listed below)\"}]}]}\u003c\/script\u003e","brand":"Nora Lighting","offers":[{"title":"120\/277V input; Triac \/ ELV \/ 0-10V dimming","offer_id":45025897218090,"sku":"LM-NORA-NHIOICDCP-425LE4","price":164.61,"currency_code":"USD","in_stock":true},{"title":"w\/ EM Driver \/ 120V-277V input; Triac \/ ELV \/ 0-10V dimming","offer_id":45025897250858,"sku":"LM-NORA-NHIOICDCP-425LE4-EM2","price":396.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0119\/3052\/files\/NHIOICD-4X_e624197a-265d-4c3a-8cd1-fd3973b13800.jpg?v=1793728611","url":"https:\/\/www.loftmodern.com\/products\/4-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-28w-nhioicdcp-425-by-nora","provider":"LoftModern","version":"1.0","type":"link"}