{"product_id":"1-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-nhioicdcp-16-by-nora","title":"1\" Iolite LED Dedicated Chicago Plenum New Construction Housing | Nora NHIOICDCP-16","description":"\u003cdiv class=\"lm-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eNora's NHIOICDCP-16\u003c\/strong\u003e is the Chicago Plenum new construction housing for 1\" Iolite trims and iPoint monopoints. It holds the driver; the trim you choose carries the LED and decides the look.\u003c\/p\u003e\n\u003cp\u003eThe driver slides out from the room side without tools, so service later does not mean opening the ceiling.\u003c\/p\u003e\n\u003cdiv class=\"lm-badges lm-ratings\" style=\"display:flex;flex-wrap:wrap;gap:8px;margin:12px 0 18px\"\u003e\n\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 3l7 3v5c0 4.5-3 8.3-7 10-4-1.7-7-5.5-7-10V6l7-3z\"\u003e\u003c\/path\u003e\u003cpath d=\"M8.5 12l2.5 2.5 4.5-5\"\u003e\u003c\/path\u003e\u003c\/svg\u003ecULus listed\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 4c-2.5 3.5-4.5 6-4.5 8.5a4.5 4.5 0 009 0C16.5 10 14.5 7.5 12 4z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eDamp location (wet with listed trim)\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003crect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\"\u003e\u003c\/rect\u003e\u003cpath d=\"M9 9v6M12 9v6M15 9v6\"\u003e\u003c\/path\u003e\u003c\/svg\u003eIC rated\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M13 3L5 13h6l-1 8 8-10h-6l1-8z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eAirtight ASTM E283\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003ccircle cx=\"12\" cy=\"9\" r=\"5.5\"\u003e\u003c\/circle\u003e\u003cpath d=\"M9 13.8L8 21l4-2 4 2-1-7.2\"\u003e\u003c\/path\u003e\u003cpath d=\"M10 9l1.5 1.5L14.5 7.5\"\u003e\u003c\/path\u003e\u003c\/svg\u003e5-year warranty\u003c\/span\u003e\u003cspan style=\"display:inline-flex;align-items:center;gap:6px;padding:6px 12px;background:#e3f2fd;color:#0d2a4a;border-radius:999px;font-size:13px;font-weight:600;line-height:1.2\"\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M5 19c0-8 5-13 14-14-1 9-6 14-14 14z\"\u003e\u003c\/path\u003e\u003cpath d=\"M5 19l8-8\"\u003e\u003c\/path\u003e\u003c\/svg\u003eRoHS\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBuilt for the Ceiling You Have\u003c\/h2\u003e\n\u003cp\u003eIt is IC rated for direct contact with insulation (not spray foam) and airtight to ASTM E283, under 2 cubic feet per minute of air leakage, which helps with energy code inspections. This is the Chicago Plenum version, for jobs where the electrical code calls for it.\u003c\/p\u003e\n\u003cp\u003eChoose LE3 for 120V with Triac\/ELV dimming (9W), or LE4 for 120-277V with Triac\/ELV\/0-10V dimming (10W). Either way the source is the same 600 lm Iolite LED in the trim.\u003c\/p\u003e\n\u003ch2\u003eIn the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e0.040\" aluminum shallow housing for a 1\/2\" ceiling\u003c\/li\u003e\n\u003cli\u003eTool-less slide-out driver assembly (LE3 120V or LE4 120-277V, as selected)\u003c\/li\u003e\n\u003cli\u003eTwo adjustable bar hangers, 13-3\/4\" to 24-1\/2\", with captive nails and T-bar notch\u003c\/li\u003e\n\u003cli\u003ePre-wired 25 cu. in. galvanized steel junction box with seven 1\/2\" knockouts and Romex strain relief\u003c\/li\u003e\n\u003cli\u003eEM2 versions only: compact emergency driver on the junction box (90 minutes at 6W in emergency mode, 24-hour recharge, 3W while charging), with remote test switch and 3' cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot in the box: the trim (the LED and optics come with the trim). Access from above the ceiling is needed; for room-side access use the remodel housing.\u003c\/p\u003e\n\u003ch2\u003eChoose Your Trim (Required)\u003c\/h2\u003e\n\u003cp\u003eBoth 1\" BWF and NTF trims fit this housing, as do the 1\" iPoint monopoints. Trims with a wet listing make the installed fixture wet rated.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-round-reflector-600lm-niob-1rng-by-nora\"\u003eNIOB-1RNG\u003c\/a\u003e – BWF round reflector\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-square-reflector-with-round-aperture-600lm-niob-1sng-by-nora\"\u003eNIOB-1SNG\u003c\/a\u003e – BWF square reflector, round aperture\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-round-bullnose-600lm-niob-1rnb-by-nora\"\u003eNIOB-1RNB\u003c\/a\u003e – BWF round bullnose\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-square-bullnose-600lm-niob-1snb-by-nora\"\u003eNIOB-1SNB\u003c\/a\u003e – BWF square bullnose\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-round-pinhole-600lm-niob-1rph-by-nora\"\u003eNIOB-1RPH\u003c\/a\u003e – BWF round pinhole\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-bwf-round-adjustable-slot-aperture-600lm-niob-1rsl-by-nora\"\u003eNIOB-1RSL\u003c\/a\u003e – BWF round adjustable slot\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-ntf-round-reflector-600lm-nio-1rng-by-nora\"\u003eNIO-1RNG\u003c\/a\u003e – NTF round reflector\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-ntf-square-reflector-with-round-aperture-600lm-nio-1sng-by-nora\"\u003eNIO-1SNG\u003c\/a\u003e – NTF square reflector, round aperture\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-ntf-round-bullnose-600lm-nio-1rnb-by-nora\"\u003eNIO-1RNB\u003c\/a\u003e – NTF round bullnose\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-iolite-led-ntf-square-bullnose-600lm-nio-1snb-by-nora\"\u003eNIO-1SNB\u003c\/a\u003e – NTF square bullnose\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-ipoint-monopoint-luminaire-round-cone-900lm-90-cri-niop-1rtc-by-nora\"\u003eNIOP-1RTC\u003c\/a\u003e – iPoint 1\" cone monopoint\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/1-inch-ipoint-monopoint-luminaire-round-cylinder-750lm-4000k-90-cri-niop-1rcy-by-nora\"\u003eNIOP-1RCY\u003c\/a\u003e – iPoint 1\" cylinder monopoint\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePairs Well With\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"\/products\/2-inch-ceiling-extension-collar-for-2-inch-and-4-inch-iolite-new-construction-housings-nio-1extc2-by-nora\"\u003eNIO-1EXTC2\u003c\/a\u003e – Extension collar for ceilings thicker than 1\/2\", up to 2\"\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ctable class=\"lm-table\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eNora Lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eNHIOICDCP-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCollection\u003c\/th\u003e\n\u003ctd\u003eIolite 1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eRecessed housing, new construction (Chicago Plenum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCeiling Cut-Out\u003c\/th\u003e\n\u003ctd\u003e2-1\/4\" (5.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eCeiling Thickness\u003c\/th\u003e\n\u003ctd\u003e1\/2\" as supplied; up to 2\" with NIO-1EXTC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003eLE3: 120V, 9W. LE4: 120-277V, 10W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eDimming\u003c\/th\u003e\n\u003ctd\u003eLE3: Triac \/ ELV. LE4: Triac \/ ELV \/ 0-10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003e600 lm Iolite LED (in the trim)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003ePower Factor\u003c\/th\u003e\n\u003ctd\u003e0.90 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eEmergency Options\u003c\/th\u003e\n\u003ctd\u003eEM2 integrated emergency driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eBar Hangers\u003c\/th\u003e\n\u003ctd\u003e13-3\/4\" to 24-1\/2\" adjustable, parallel or turned 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eJunction Box\u003c\/th\u003e\n\u003ctd\u003e25 cu. in., 0.064\" galvanized steel, up to 8 no. 12 AWG through-branch conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eInsulation Contact\u003c\/th\u003e\n\u003ctd\u003eIC rated (not for direct contact with spray foam)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eAir Tightness\u003c\/th\u003e\n\u003ctd\u003eASTM E283, under 2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eSafety Listing\u003c\/th\u003e\n\u003ctd\u003ecULus listed for damp locations; wet with a wet-listed trim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eEnvironmental\u003c\/th\u003e\n\u003ctd\u003eRoHS compliant; FCC compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:36%;min-width:8.5em;overflow-wrap:normal;word-break:normal\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5-year limited warranty (Nora Lighting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpec Sheets \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2019\/02\/NHIOICD-16_spec.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpec sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2018\/05\/IS-NHIOICD-16.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2020\/04\/Iolite-Catalog.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIolite collection catalog (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/noralighting.com\/wp-content\/uploads\/2019\/02\/Limited-Warranty-Five-Year.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNora 5-year limited warranty (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/n2aYcDFuVWA\" target=\"_blank\" rel=\"noopener\"\u003eProduct video\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot the Right Fit If…\u003c\/h2\u003e\n\u003cp\u003eYou are working in a finished ceiling with no access from above. Choose the NHRIOIC-16 remodel housing instead. The Chicago Plenum version has no pre-wired remote emergency (PEM) option.\u003c\/p\u003e\n\u003ch2\u003eQuestions We Hear Most\u003c\/h2\u003e\n\u003ch3\u003eDoes the housing include the light?\u003c\/h3\u003e\n\u003cp\u003eNo. The LED and optics come with the 1\" Iolite trim or iPoint you pair it with. The housing supplies the driver.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between LE3 and LE4?\u003c\/h3\u003e\n\u003cp\u003eLE3 runs on 120V with Triac\/ELV dimming at 9W. LE4 runs on 120-277V and adds 0-10V dimming, at 10W.\u003c\/p\u003e\n\u003ch3\u003eWhat does the EM2 option do?\u003c\/h3\u003e\n\u003cp\u003eIt adds an emergency driver that keeps the light on for 90 minutes at 6W during an outage. The battery draws 3W while it charges.\u003c\/p\u003e\n\u003ch3\u003eCan it touch insulation?\u003c\/h3\u003e\n\u003cp\u003eYes, it is IC rated for direct contact with insulation, but not with spray foam.\u003c\/p\u003e\n\u003ch3\u003eMy ceiling is thicker than 1\/2\". Will it fit?\u003c\/h3\u003e\n\u003cp\u003eAdd the NIO-1EXTC2 extension collar for ceilings up to 2\" thick, the maximum for any install.\u003c\/p\u003e\n\u003ch2\u003eWhy We Love It\u003c\/h2\u003e\n\u003cp\u003eA 1\" downlight lives or dies by its housing. This one keeps the driver serviceable from below and the ceiling airtight above.\u003c\/p\u003e\n\u003ch2\u003eShipping Info\u003c\/h2\u003e\n\u003ctable class=\"lm-shipping-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing Time\u003c\/th\u003e\n\u003ctd\u003eIn-stock items typically leave within 2–3 business days.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShips From\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003eFree shipping on orders over $100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFind Your Part Number\u003c\/h2\u003e\n\u003cp\u003eEach light output and driver combination on this page is its own Nora part number (for example NHIOICDCP-16LE3 or LE4, with \/EM2), shown as the SKU when you select it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@graph\": [{\"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Does the housing include the light?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. The LED and optics come with the 1\\\" Iolite trim or iPoint you pair it with. The housing supplies the driver.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between LE3 and LE4?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"LE3 runs on 120V with Triac\/ELV dimming at 9W. LE4 runs on 120-277V and adds 0-10V dimming, at 10W.\"}}, {\"@type\": \"Question\", \"name\": \"What does the EM2 option do?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It adds an emergency driver that keeps the light on for 90 minutes at 6W during an outage. The battery draws 3W while it charges.\"}}, {\"@type\": \"Question\", \"name\": \"Can it touch insulation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, it is IC rated for direct contact with insulation, but not with spray foam.\"}}, {\"@type\": \"Question\", \"name\": \"My ceiling is thicker than 1\/2\\\". Will it fit?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Add the NIO-1EXTC2 extension collar for ceilings up to 2\\\" thick, the maximum for any install.\"}}]}, {\"@id\": \"\/products\/1-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-nhioicdcp-16-by-nora#product\", \"@type\": \"ProductGroup\", \"name\": \"Nora 1\\\" Iolite Chicago Plenum New Construction Housing NHIOICDCP-16\", \"productGroupID\": \"NHIOICDCP-16\", \"brand\": {\"@type\": \"Brand\", \"name\": \"Nora Lighting\"}, \"manufacturer\": {\"@type\": \"Organization\", \"name\": \"Nora Lighting\", \"url\": \"https:\/\/noralighting.com\"}, \"category\": \"Recessed housing\", \"variesBy\": [\"Light Output\", \"Voltage \u0026 Driver\"], \"material\": \"Aluminum housing, galvanized steel junction box\", \"additionalProperty\": [{\"@type\": \"PropertyValue\", \"name\": \"Brand\", \"value\": \"Nora Lighting\"}, {\"@type\": \"PropertyValue\", \"name\": \"Model Number\", \"value\": \"NHIOICDCP-16\"}, {\"@type\": \"PropertyValue\", \"name\": \"Collection\", \"value\": \"Iolite 1\\\"\"}, {\"@type\": \"PropertyValue\", \"name\": \"Product Type\", \"value\": \"Recessed housing, new construction (Chicago Plenum)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Ceiling Cut-Out\", \"value\": \"2-1\/4\\\" (5.7 cm)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Ceiling Thickness\", \"value\": \"1\/2\\\" as supplied; up to 2\\\" with NIO-1EXTC2\"}, {\"@type\": \"PropertyValue\", \"name\": \"Input Power\", \"value\": \"LE3: 120V, 9W. LE4: 120-277V, 10W\"}, {\"@type\": \"PropertyValue\", \"name\": \"Dimming\", \"value\": \"LE3: Triac \/ ELV. LE4: Triac \/ ELV \/ 0-10V\"}, {\"@type\": \"PropertyValue\", \"name\": \"Light Source\", \"value\": \"600 lm Iolite LED (in the trim)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Power Factor\", \"value\": \"0.90 or higher\"}, {\"@type\": \"PropertyValue\", \"name\": \"Emergency Options\", \"value\": \"EM2 integrated emergency driver\"}, {\"@type\": \"PropertyValue\", \"name\": \"Bar Hangers\", \"value\": \"13-3\/4\\\" to 24-1\/2\\\" adjustable, parallel or turned 90°\"}, {\"@type\": \"PropertyValue\", \"name\": \"Junction Box\", \"value\": \"25 cu. in., 0.064\\\" galvanized steel, up to 8 no. 12 AWG through-branch conductors\"}, {\"@type\": \"PropertyValue\", \"name\": \"Insulation Contact\", \"value\": \"IC rated (not for direct contact with spray foam)\"}, {\"@type\": \"PropertyValue\", \"name\": \"Air Tightness\", \"value\": \"ASTM E283, under 2 CFM\"}, {\"@type\": \"PropertyValue\", \"name\": \"Operating Temperature\", \"value\": \"40°C max.\"}, {\"@type\": \"PropertyValue\", \"name\": \"Safety Listing\", \"value\": \"cULus listed for damp locations; wet with a wet-listed trim\"}, {\"@type\": \"PropertyValue\", \"name\": \"Environmental\", \"value\": \"RoHS compliant; FCC compliant\"}, {\"@type\": \"PropertyValue\", \"name\": \"Warranty\", \"value\": \"5-year limited warranty (Nora Lighting)\"}]}]}\u003c\/script\u003e","brand":"Nora Lighting","offers":[{"title":"9W \/ 120V input; Triac \/ ELV dimming","offer_id":45025921794090,"sku":"LM-NORA-NHIOICDCP-16LE3","price":93.15,"currency_code":"USD","in_stock":true},{"title":"9W \/ w\/ EM Driver \/ 120V input; Triac \/ ELV dimming","offer_id":45025921826858,"sku":"LM-NORA-NHIOICDCP-16LE3-EM2","price":325.35,"currency_code":"USD","in_stock":true},{"title":"10W \/ 120-277V input; Triac \/ ELV \/ 0-10V dimming","offer_id":45025921859626,"sku":"LM-NORA-NHIOICDCP-16LE4","price":123.75,"currency_code":"USD","in_stock":true},{"title":"10W \/ w\/ EM Driver \/ 120V-277V input; Triac \/ ELV \/ 0-10V dimming","offer_id":45025921892394,"sku":"LM-NORA-NHIOICDCP-16LE4-EM2","price":355.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0119\/3052\/files\/NHIOICD_NHIOICDCP_01c33156-a5d0-44f4-8245-af2fd452a1cb.jpg?v=1793728834","url":"https:\/\/www.loftmodern.com\/products\/1-inch-iolite-led-dedicated-chicago-plenum-new-construction-housing-nhioicdcp-16-by-nora","provider":"LoftModern","version":"1.0","type":"link"}